AVEVA Device Communication Hardware Compatibility Guide

AVEVA Device Communication Hardware Compatibility Guide

Allen Bradley

      OIABCIP v.7.2 (Allen Bradley - ABCIP Driver):

- ControlLogix (L5x/L6x: up to Firmware 20 | L7x: up to Firmware 33 | L8xE: up to Firmware 33);

- GuardLogix (L6xS: up to Firmware 20 | L7xS: up to Firmware 33 | L8xES: up to Firmware 33);

- CompactLogix (1768/9-Lx: up to Firmware 20 | 1769-LxxER*: up to Firmware 33 | 5069-LxxxER*: up to Firmware 33);

- Compact GuardLogix (1768-LxxS: up to Firmware 20 | 1769-LxxER*S: up to Firmware 33 | 5069-LxxxER*S2: up to Firmware 33);

- FlexLogix (Lxx: up to Firmware 16);

- SoftLogix (Lx: up to Firmware 23);

- MicroLogix (1100: up to Firmware 16 | 1200/1500: up to Firmware 14 | 1400:up to Firmware 21);

- PLC-5;

- SLC500.

      OIABTCP v.7.2 (Allen Bradley - ABTCP Driver):

- PLC-5E (Ethernet based);

- PLC-5 with Ethernet Communication Module;

- SLC505.

General Electric GE

      OIGESRTP v.7.2 (General Electric GE - GESRTP):

- Series 90-30;

- Series 90-70;

- Versamax;

- Versamax Micro;

- Versamax Nano;

- PACSystems (RX3i, RX7i).


Modbus    

OIMBTCP v.7.2 (Modbus - MBTCP):

- TSX Quantum;

- TSX Momentum;

- TSX Premium;

- Generic Modbus TCP;

- Compact 984 (thru Modbus Bridge);

- Modicon Micro (thru Modbus Bridge);

- Generic Modbus Serial (thru Modbus Bridge).


Siemens

OISIDIR v.7.2 (Siemens - SIDirect):

- S7-200

  • Not Supported

 

- S7-300

  • Supported up to firmware version 3.03.17

  • Polling / Cyclic mode Supported

  • Standard CPU

  • Compact CPU

  • Fail-safe CPU

 

- S7-400 (S7-400H)

  • S7-400 - Supported up to firmware version v7.00.02

  • S7-400H - Supported up to firmware version v6.00.09

  • Polling / Cyclic mode Supported

  • Standard CPU

  • Fail-safe CPU

  • High-Availability CPU

 

- S7-1200 Basic Controllers

  • Supported up to firmware version v4.04.01

  • Minimum Firmware For Legacy connections minimum firmware version is 1.0.0

  • Minimum Firmware For Symbolic connections minimum firmware version is 4.0.0

  • Polling / Cyclic / Symbolic mode Supported

  • Standard CPUs

  • Fail-safe CPUs

 

- S7-1500 Software Controllers

  • Supported up to firmware version v2.08.03

  • Minimum Firmware For Legacy connections minimum firmware version is 1.0.0

  • Minimum Firmware For Symbolic connections minimum firmware version is 1.5.0

  • Compact CPUs

  • Standard CPUs

  • Fail-safe CPUs

  • Technology CPUs

  • MFP CPUs

  • Redundant CPUs

  • High-Availability CPUs

 

- SIMATIC ET 200 Distributed Controllers

  • Not Supported

 

- SIMATIC S7-PLCSIM Advanced v2.0

  • Not Supported
Omron 

 OMRONFINS v.7.2 (Omron - OMRONFINS):

Supports the Omron PLCs on a FINS network:

  • CJ1 Series
  • CJ2 Series
  • CS1 Series
  • CP1 Series
  • CV Series
  • CVM1
  • CVM1D Series

The following platforms support the FINS protocol, but were not tested. As such compatibility cannot be guaranteed.

  • C200 Series
  • NJ Series
  • NX Series
  • NSJ Series